Search

  • HOME
  • Search
Review Article
Neurology
Health effects of electromagnetic fields on children
Jin-Hwa Moon
Clin Exp Pediatr. 2020;63(11):422-428.   Published online May 26, 2020
· The nervous systems of children are more vulnerable to the effects of electromagnetic waves than adults.
· The exposure to electromagnetic fields (EMFs) among children should be minimized.
· According to International Agency for Research on Cancer EMFs are possibly carcinogenic, it should not be overlooked or interpreted with bias.
Comprehensive understanding of atrial septal defects by imaging studies for successful transcatheter closure
Jinyoung Song
Clin Exp Pediatr. 2014;57(7):297-303.   Published online July 23, 2014

Transcatheter closure of atrial septal defects has become a popular procedure. The availability of a preprocedural imaging study is crucial for a safe and successful closure. Both the anatomy and morphology of the defect should be precisely evaluated before the procedure. Three-dimensional (3D) echocardiography and cardiac computed tomography are helpful for understanding the morphology of a defect, which is important...

Original Article
Transcatheter closure of small ductus arteriosus with amplatzer vascular plug
Eun Hyun Cho, Jinyoung Song, I-Seok Kang, June Huh, Sang Yoon Lee, Eun Young Choi, Soo Jin Kim
Clin Exp Pediatr. 2013;56(9):396-400.   Published online September 30, 2013
Purpose

The purpose of this study was to share our experience of transcatheter closure of small patent ductus arteriosus (PDA) by using an Amplatzer vascular plug (AVP).

Methods

We reviewed the medical records of 20 patients who underwent transcatheter closure at Samsung Medical Center and Sejong General Hospital from January 2008 to August 2012. The size and shape of the PDAs were evaluated...

The hybrid perventricular closure of apical muscular ventricular septal defect with Amplatzer duct occluder
Soo Jin Kim, June Huh, Jin Young Song, Ji-Hyuk Yang, Tae-Gook Jun, I-Seok Kang
Clin Exp Pediatr. 2013;56(4):176-181.   Published online April 22, 2013
Purpose

Apical muscular ventricular septal defects (MVSDs), especially in small infants, can be difficult to manage using surgical and percutaneous closure. An intraoperative perventricular procedure is a good option for closing apical MVSDs in small children with or without associated cardiac anomalies. We evaluated the results of hybrid perventricular closure of apical MVSDs performed using an Amplatzer duct occluder (ADO).

Methods

We retrospectively...

Case Report
Transvenous proximal closure of large congenital coronary arteriovenous fistula using the single Amplatzer vascular plug in a 3-year-old girl
Hae In Jang, Young Earl Choi, Hwa Jin Cho, Young Kuk Cho, Jae Sook Ma
Clin Exp Pediatr. 2013;56(2):90-93.   Published online February 25, 2013

Congenital coronary arteriovenous fistulas (CCAFs) are rare coronary artery abnormalities in which blood is shunted into a cardiac chamber or great vessel. If the fistula itself is large and tortuous, it is generally recommended to occlude the fistula to prevent several complications. In approaches of transcatheter occlusion, the transvenous approach is preferred over the transarterial approach. The transvenous approach would...

Original Article
Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents
Chong Guk Lee, Hyang Mi Park, Hye Jung Shin, Jin Soo Moon, Yeong Mi Hong, Nam Soo Kim, Il Soo Ha, Myeong Jin Chang, Kyeong Won Oh
Clin Exp Pediatr. 2011;54(11):463-469.   Published online November 30, 2011
Purpose

To validate the Dinamap ProCare 200 blood pressure (BP) monitor against a mercury sphygmomanometer in children 7 to 18 years old in accordance with the 2010 International Protocol of European Society of Hypertension (ESH-IP2) and the British Hypertension Society (BHS) protocol.

Methods

Forty-five children were recruited for the study. A validation procedure was performed following the protocol based on the ESH-IP2 and...

Clinical outcome of transcatheter closure of patent ductus arteriosus in small children weighing 10 kg or less
Young A Park, Nam Kyun Kim, Su-Jin Park, Bong Sic Yun, Jae Young Choi, Jun Hee Sul
Clin Exp Pediatr. 2010;53(12):1012-1017.   Published online December 31, 2010
Purpose

Transcatheter closure has become an effective therapy in most patients with patent ductus arteriosus (PDA). However, there are difficulties in transcatheter closure of PDA in small children. We reviewed clinical outcomes of transcatheter closure of PDA in children weighing less than 10 kg in a single center.

Methods

Between January 2003 and December 2009, 314 patients with PDA underwent transcatheter closure in...

Case Report
Use of an Amplatzer Vascular Plug to occlude a tubular type of patent ductus arteriosus
Eun-Young Choi, So-Ick Jang, Soo-Jin Kim
Clin Exp Pediatr. 2009;52(9):1035-1037.   Published online September 15, 2009
Patent ductus arteriosus (PDA) is a common congenital heart defect. All PDAs, regardless of size or degree of symptoms, require occlusion. Transcatheter PDA occlusion features fewer complications than trans-thoracic closure. It is also more cost-effective and has an excellent occlusion rate. Therefore, transcatheter PDA occlusion is accepted as the standard treatment option for PDA. However, tubular-type PDAs are difficult to...
Original Article
The efficacy and safety of transcatheter closure of atrial septal defect with Amplatzer septal occluder in young children less than 3 years of age
Soo Hyun Lee, Deok Young Choi, Nam Kyun Kim, Jae Young Choi, Jun Hee Sul
Clin Exp Pediatr. 2009;52(4):494-498.   Published online April 15, 2009
Purpose : Applicability of transcatheter closure of atrial septal defect (ASD) has been expanded by accumulation of clinical experiences and evolutions of the device. This study was performed to evaluate the safety and efficacy of transcatheter closure of ASD with Amplatzer septal occluder (ASO) in young children less than 3 years of age. Methods : From May 2003 to December...
Review Article
Normative blood pressure references for Korean children and adolescents
Chong Guk Lee, Jin Soo Moon, Joong-Myung Choi, Chung Mo Nam, Soon Young Lee, Kyungwon Oh, Young Taek Kim
Clin Exp Pediatr. 2008;51(1):33-41.   Published online January 15, 2008
Purpose : It is now understood that blood pressure (BP) measurement in the routine pediatric examination is very important because of the relevance of childhood BP to pediatric health care and the development of adult essential hypertension. There hasn't been a reference table of BP for Korean children and adolescents up to now. This study was to make normative BP...
Original Article
Transcatheter Closure of the Patent Ductus Arteriosus
Young A Lee, Myung Chul Hyun, Sang Bum Lee
Clin Exp Pediatr. 2000;43(9):1200-1206.   Published online September 15, 2000
Purpose : Transcatheter closure of the patent ductus arteriosus(PDA) is a well-established, effective therapeutic modality, and many kinds of devices have been used to perform this closure. The aim of this study is to compare the effects of different kinds of devices. Methods : We reviewed retrospectively the charts of 43 patients who were admitted to Kyungpook University Hospital between June...
Midterm Result after Transcatheter Occlusion of Patent Ductus Arteriosus with Rashkind PDA Umbrella Device
Chung Il Noh, Eun Sook Han, Ho Sung Kim, Jung Yun Choi, Yong Soo Yun
Clin Exp Pediatr. 1995;38(5):668-674.   Published online May 15, 1995
Purpose : To evaluate the appropriateness of the transcatheter occlusion with Rashkind um-brella occlusion device Methods : Among the 54 cases who had been tried transcatheter closure of patent ductus ar teriosus from January, 1992 till December, 1993 at Seoul National Univerity Children's Hospital, the first follow-up evaluation with Doppler echocardioram were done in 43 cases at the mean i-nterval of...
Erratum
Transcatheter Closure of Secundum Atrial Septal Defect with \Buttoned\" Device"
Jong-Kyun Lee, Seok Min Choi, Jo Won Jung, Jun Hee Sul, Sung Kyu Lee, Jin Yong Lee, Hae Yong Lee
Accepted January 1, 1970  
Purpose : Recently, non-operative transcatheter management of congenital heart defects h as increased due to their effectiveness and safety being acknowledged. In the case of secundu- m atrial septal defect(ASD), closing devices have been developed since 1974 and have been u sed clinically. The authors, having tried the "Buttoned" device which was developed in 1990 an d having succeeded in...
Original Article
A Prospective Study of Totally Implanted Venous Access System in 19 Children with Cancer
Kyung Duk Park, Eun Sil Dong, Seong Hoon Ha, Hong Hoe Koo, Hee Young Shin, Hyo Seop Ahn, Seong Eun Jun, Gui Won Park
Clin Exp Pediatr. 1993;36(5):687-692.   Published online May 15, 1993
A totally implanted venous access system was inserted in 19 children with cancer. The devices were utilized for the administration of antineoplastic drug, parenteral fluids, antibiotics, and blood products. Total duration of implantation was 4,046 days for 23 implanted system (range 7-445 days). Complications included cather infection (0.247/100 catheter day), occlusion (0.692/100 catheter days), and dislodgement of needle (0.643/100 catheter...
  • PubMed Central
  • PubMed
  • Scopus
  • Directory of Open Access Journals (DOAJ)