Comparison of Pulmonary and Systemic Blood Flow and Ratio of Pulmonary Blood Flow to Systemic Blood Flow Obtained by Pulsed Wave Doppler Echocardiography and Fick Method.

Journal of the Korean Pediatric Society 1987;30(9):982-989.
Published online September 30, 1987.
Comparison of Pulmonary and Systemic Blood Flow and Ratio of Pulmonary Blood Flow to Systemic Blood Flow Obtained by Pulsed Wave Doppler Echocardiography and Fick Method.
Sung Gy Jin, Myeng Hee Cha, Kyeng Sook Cho, Doo Sung Moon
Department of Pediatrics, Maryknoll Hospital, Pusan, Korea
간헐파형 Doppler 심초음파와 Fick법을 이용하여 측정한 폐혈류량,체혈류량과 그 비율의 비교 관찰
진성기, 차명희, 조경숙, 문두성
부산 메리놀병원 소아과
Abstract
This study was designed to assess the accuracy of pulsed wave Doppler echocardiographic measurement of pulmonary blood flow(Qp), systemic blood flow(Qs) and the ratio of pulmonary blood flow to systemic blood flow(Qp/Qs) to compare with Fick method. Seventeen patients with ventricular septal defect, aged 10 months to 14 years, participated for this study, and Doppler echocardiograghic examinations using the Aloka SSD-880 were performed. Two dimensional Doppler echocardiographic measurements of pulmonary blood flow were obtained by parasternal short axis view, and systemic blood flow by suprasternal notch view. In all patients cardiac catheterizations were performed within 48 hours after examination of Doppler echocardiography, and Qp, Qs, Qp/Qs ratio were calculated by using Fick method. Problems encountered in some patients included turbulent blood flow, alising, difficulty in measur- ing of pulmonary artery diameter by 2-D echocardiography and difficulty in obtaining of aortic blood flow by pulsed wave Doppler echocardiography. Comparison of Qp, Qs, Qp/Qs ratio obtained by pulsed wave Doppler echocardiography and with those by Fick method was well correlated (correlation coefficient was 0.750 in Qp, 0.738 in Qs and 0.809 in Qp/Qs ratio).
Key Words: Pulsed wave Doppler echocardiography, Fick method, Qp, Qs, Qp/Qs ratio.